COMPTEL SPECIFICATIONS
1. Detectors:
a. Detector type:
1) upper detector D1: liquid scintillator NE 213A
2) lower detector D2: NaI(Tl)
b. Geometric arrangement:
1) D1: 7 cylindrical modules 27.6 cm in diameter and
8.5 cm deep; total geometric area 4188 cm2
2) D2: 14 cylindrical modules 28 cm in diameter and
7.5 cm deep; total geometric area 8620 cm2
c. Effective area for gamma-rays: 20 - 50 cm2
(no event selections applied to the data)
d. Energy range: 0.8 - 30 MeV
e. Energy resolution: 5 - 8% (FWHM)
f. Angular resolution: 1.7 - 4.4 degrees (FWHM)
g. Geometric factor: 5 - 30 cm2 sr
h. Field-of-view: 1 sr
i. Accuracy of Source Position Determination: 5 - 30 arcmin
2. Experiment Sensitivities:
a. Telescope Observations of a Point Source
1) Minimum source detectability at 3 sigma, 1-30 MeV
(2-week observation)
= 1.6 x 10-4 cm-2 s-1
2) Line sensitivity
(3 sigma, 2-week observation)
= 6 x 10-5 cm-2 s-1 at 1 MeV
= 1.5 x 10-5 cm-2 s-1 at 7 MeV
b. Burst Observations
1) Telescope mode
lower limit: S(>1 MeV) = 2 x 10-6 erg cm-2
upper limit: S(>1 MeV) = 1 x 10-4 erg cm-2 (45 s duration)
2) Single detector burst mode
variable, depending on duration
c. Solar Flare Observations
1) Telescope mode
= 1.2 ph cm-2 (1-3 MeV, 100 s duration)
= 0.5 ph cm-2 (3-10 MeV, 100 s duration)
2) Single detector burst mode
as for burst observations, above
3. Miscellaneous Instrument Specifications:
a. Weight: 1460 kg
b. Dimensions: 2.61 m x 1.76 m diameter
c. Power: 206 W
d. Telemetry Rate: 6125 bit/s (equivalent time-average)
e. Timing accuracy: +/- 1/8 msec with respect to UTC.